V/Ethernet 4221 Condor
User’s Guide
Document No. UG04221-000, REVB
Release date: July 1994
Copyright 1994
Interphase Corporation
All Rights Reserved
Vue de la page 0
1 2 3 4 5 6 ... 123 124

Résumé du contenu

Page 1 - User’s Guide

V/Ethernet 4221 Condor User’s GuideDocument No. UG04221-000, REVBRelease date: July 1994Copyright 1994Interphase CorporationAll Rights Reserved

Page 3 - Disclaimer

Chapter 3 - MACSI Host Interface88Command Options Table 3-30. Command OptionsInterrupt enable (IE) As defined in Common IOPB Structures. In-line gathe

Page 4 - Trademark Acknowledgments

Transmit -- In-Line Gathers89Table 3-31. Transmit - In-Line GathersNumber of Elements This field contains the number of gather elements included in th

Page 5 - TABLE OF CONTENTS

Chapter 3 - MACSI Host Interface90Receive The host provides the controller with Receive commands, which specify the host resources to be used for inco

Page 6

Receive91Command Code This field must contain 0x60 to execute the Receive IOPB. Command Options Table 3-33. Command OptionsInterrupt enable As defined

Page 7

Chapter 3 - MACSI Host Interface92Source Address When so monitoring the network, the source address for the incoming frame will be contained in this f

Page 8

Initialize Multiple Completions93Initialize Multiple Completions This command enables the controller to return multiple completed commands to the host

Page 9 - LIST OF FIGURES

Chapter 3 - MACSI Host Interface94Command Options No special options are available for this command. Refer to Common IOPB structures for defined opti

Page 10

Report Network Statistics95Report Network Statistics Table 3-36. Report Network StatisticsThe Report Network Statistics Command can be used to obtain

Page 11 - LIST OF TABLES

Chapter 3 - MACSI Host Interface96Command Options Table 3-37. Command OptionsInterrupt enable (IE) As defined in Common IOPB Structures. Port selector

Page 12

Network Statistics Block97Network Statistics Block Table 3-38. Network Statistics BlockData Valid Indicator When the data is transferred to the host,

Page 13 - INTRODUCTION

LIST OF TABLESxivTable 2-1. Condor Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 14 - Features

Chapter 3 - MACSI Host Interface98Transmits Failed This field contains the number of transmit commands for the particular port that could not be trans

Page 15 - Functional Description

99APPENDIX A SPECIFICATIONSVMEbus SpecificationsDTB Master A16, A24, A32, D08 (EO), D16, D32: BLT, D64: BLTDTB Slave A16, D08 (EO), D16, D32Request

Page 16 - Local Bus

100Appendix AMechanical (Nominal)Length 233 mmWidth 160 mmThickness 20 mmWeight .45 KgOperating EnvironmentTemperature 0-55 degrees CentigradeRelative

Page 17 - CPU Core

101APPENDIX B CONNECTOR PINOUTS AND CABLINGOverviewThis chapter contains the connector pinouts and cabling information needed for various Condor confi

Page 18 - CPU/LBUS Interface

102Appendix BVMEbus ConnectorsThe following tables show the pin numbers and signal description for the P1 and P2 VMEbus Connectors.• Table C-39 - P1 C

Page 19 - HARDWARE INSTALLATION

103VMEbus ConnectorsP2 Connector Row B Only VersionTable C-40. P2 Connector For Motherboards Which Only Uses P2 Row BPINRow A Signal Mnemonic Row B Si

Page 20

104Appendix BEthernet Connectors and PinoutsThe Condor supports both the AUI and 10BaseT versions of the Ethernet 802.3 specification. The card will h

Page 21 - DAUGHTER

105Ethernet Connectors and PinoutsAUI Connector SignalsThe AUI signals and connector pinout for the DB15 connector are shown in the following table.Ta

Page 22

106Appendix BRS232 Connector and CableTable C-43. Serial Connector Pinouts (SPA and SPB)NOTE: The same cable for the second Serial Port for PC compa

Page 23

107APPENDIX C ERROR CODESThe Return Status word in the command response contains information pertaining to the status of the IOPBs returnedin the Comm

Page 24

xvTable 3-36. Report Network Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Tab

Page 25

108Appendix B

Page 26 - Diagnostic LEDs

INDEX109Numerics82596 4, 81, 82AAA 79Abort ALL (AA) 79Abort ANY (AN) 79Abort Pending (AP) 81Abort Report (AR) 80, 81Air Flow 100AN 79ANY 91AP 81AR

Page 27 - Board Status LEDs

110EX 63Exception (EX) 63Ffeature list 2fetch offboard entry (FOB) 60Fetch offboard in progress (FIP) 60field offset 54FIP 60firmware revision level 6

Page 28 - Motherboard Jumper Settings

111PPFM 86PM 75, 81POST mode 15power requirements 99Product Code 65, 68Program factory MAC address (PFM) 86Promiscuous mode (PM) 75, 81QQECR 60QMS

Page 30 - J14 Firmware Option Jumpers:

1CHAPTER 1 INTRODUCTIONIntended AudienceInterphase wrote this manual for its customers. It is intended for a highly technical audience, specifically,

Page 31

Chapter 1 - Introduction2ConventionsThis section details many of the writing conventions used throughout the manual. In addition, it gives many of th

Page 32

Options3OptionsInterphase Corporation offers the following Condor options:• Dual Channel Ethernet (AUI)• Dual Channel Ethernet (10BaseT)• 3 Channel Et

Page 33

Chapter 1 - Introduction4Ethernet Front End Channel (FEC)The 82596CA® Local Area Network (LAN) Co-processor is used as the FEC Ethernet controller. Th

Page 34

VMEbus Short I/O Interface5VMEbus Short I/O InterfaceThe VMEbus Short I/O interface allows for VMEbus host and onboard CPU communications. The host is

Page 35

Chapter 1 - Introduction6interrupt handler outputs an interrupt vector number for the non-DMA engine interrupts or requests access to the LBUSfor a DM

Page 36

7CHAPTER 2HARDWARE INSTALLATIONOverviewBefore attempting installation, read this chapter thoroughly to insure the safe installation of the Condor int

Page 38

Chapter 2 - Hardware Installation8The daughter card installation procedure will vary depending on the desired configuration. Variables include:• Sing

Page 39

Overview9Figure 2-1. 10BaseT Condor Motherboard Layout (PB04221-000)LED 1LED 2LED 3LED 4LED 5LED 6LED 7SPBSPAJ14J15J16J18J12J13P2P1J23J24J26J25J19J2

Page 40

Chapter 2 - Hardware Installation10Figure 2-2. Single Channel AUI or 10BaseT Motherboard Layout (PB004221-001)LED 1LED 2LED 3LED 4LED 5LED 6SPBSPAJ1

Page 41

Overview11Figure 2-3. AUI Condor Motherboard Layout (PB04221-000)LED 1LED 2LED 3LED 4LED 5LED 6SPBSPAJ14J15J16J18J12J13P2P1J23J24J26J25J19J20J21J22

Page 42

Chapter 2 - Hardware Installation12Figure 2-4. 10BaseT Condor Motherboard Layout (PB04221-001)LED 1LED 2LED 3LED 4LED 5LED 6LED 7SPBSPAJ10 J14 J16J1

Page 43

Overview13Figure 2-5. AUI Condor Motherboard Layout (PB04221-001)LED 1LED 2LED 3LED 4LED 5LED 6SPBSPAJ10 J14J16J18J12J15P2P1J23J24J26J25J19J20J21J2

Page 44

Chapter 2 - Hardware Installation144221 Condor Hardware Installation ProceduresFor proper installation of the Condor, it is imperative that you use th

Page 45

4221 Condor Hardware Installation Procedures15Board Status LEDsLEDs 1, 2, 3, and 4 are Board Status LEDs which provide the following functions:• Power

Page 46

Chapter 2 - Hardware Installation16Table 2-4. Run Mode LED MatrixStep 3. Set Onboard Motherboard Jumpers Set all onboard jumpers so that the Condor i

Page 47

4221 Condor Hardware Installation Procedures17J9 +12 VOLTS Flash Programming Protect: IN: +12 Volt power connected to EPROM socket.OUT: +12 Volt power

Page 48

Copyright Notice Copyright 1993, 1994 by Interphase CorporationAll rights reservedNo part of this publication may be stored in a retrieval system, tr

Page 49

Chapter 2 - Hardware Installation18(Pins 5-6) Console Message DisableIN = DisableOUT = Enable(Pins 7-8) GDB Enable PointIN = GDB Initialized On ExitOU

Page 50

4221 Condor Hardware Installation Procedures19Table 2-6. Secondary Short I/O* Factory DefaultJ16 Primary Short I/O Size / Reset Enable:Table 2-7. Prim

Page 51

Chapter 2 - Hardware Installation20J18 Primary Channel Address Modifiers:IN = Primary Channel Address Modifiers 29 or 2D OUT = Primary Channel Addres

Page 52

4221 Condor Hardware Installation Procedures21J19, J20, J21 & J22 Primary Short I/O Base Address:Refer to the following tables when setting Primar

Page 53

Chapter 2 - Hardware Installation22Table 2-8. Primary Base Address For 2K Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J19 PIN SETTI

Page 54

4221 Condor Hardware Installation Procedures23Table 2-9. Primary Base Address For 1K Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J1

Page 55

Chapter 2 - Hardware Installation24Table 2-10. Primary Base Address For 512 Byte Short I/ONOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J19 PIN

Page 56

4221 Condor Hardware Installation Procedures25Table 2-10. Primary Base Address For 512 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Page 57

Chapter 2 - Hardware Installation26Table 2-11. Primary Base Address For 256 Byte Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J19 PI

Page 58

4221 Condor Hardware Installation Procedures27Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Page 59

For AssistanceTo place an order for an Interphase product, call:Sales Support: (214) 919-9000For assistance using this, or any other Interphase produ

Page 60

Chapter 2 - Hardware Installation28Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADD

Page 61

4221 Condor Hardware Installation Procedures29Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Page 62

Chapter 2 - Hardware Installation30Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADD

Page 63 - Step 6. Cabling Procedure

4221 Condor Hardware Installation Procedures31Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Lo

Page 64 - RS232 Connectors And Cables

Chapter 2 - Hardware Installation32Table 2-11. Primary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADD

Page 65 - MACSI HOST INTERFACE

4221 Condor Hardware Installation Procedures33J23, J24, J25 & J26 Secondary Short I/O Address:Refer to the following tables when setting Secondary

Page 66 - Contiguous Data Allocation

Chapter 2 - Hardware Installation34Table 2-12. Secondary Base Address For 2K Short I/ONOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS J23 PIN SET

Page 67 - MACSI Organization

4221 Condor Hardware Installation Procedures35Table 2-13. Secondary Base Address For 1K Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS

Page 68

Chapter 2 - Hardware Installation36Table 2-13. Secondary Base Address For 1K Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)ADDRESS

Page 69 - 1514131211109876543210

4221 Condor Hardware Installation Procedures37Table 2-14. Secondary Base Address For 512 Byte Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Page 70 - Master Control Register (MCR)

TABLE OF CONTENTSviCHAPTER 1INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 71 - Onboard Command Queue Entry

Chapter 2 - Hardware Installation38Table 2-14. Secondary Base Address For 512 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Page 72 - Offboard Command Queue Entry

4221 Condor Hardware Installation Procedures39Table 2-14. Secondary Base Address For 512 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F= OUT (L

Page 73 - Work Queue Number

Chapter 2 - Hardware Installation40Table 2-14. Secondary Base Address For 512 Byte Short I/O (ContinuedADDRESS J23 PIN SETTINGS J24, J25, J26 PIN SETT

Page 74 - Command Response Block (CRB)

4221 Condor Hardware Installation Procedures41Table 2-15. Secondary Base Address For 256 Byte Short I/O NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Page 75 - IOPB Length

Chapter 2 - Hardware Installation42Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Page 76 - Transfer Count

4221 Condor Hardware Installation Procedures43Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F= OUT (L

Page 77 - Product Variation

Chapter 2 - Hardware Installation44Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Page 78 - Firmware Revision Date

4221 Condor Hardware Installation Procedures45Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (

Page 79 - Controller Statistics Block

Chapter 2 - Hardware Installation46Table 2-15. Secondary Base Address For 256 Byte Short I/O (Continued)NOTE: 0 = IN (Logical 0), F = OUT (Logical 1)A

Page 80 - Failed Transmits

4221 Condor Hardware Installation Procedures47Step 4. Set Daughter Card Jumpers And TerminationsThe following daughter card settings are discussed:• E

Page 81

viiCommand Response Block (CRB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 82 - Common IOPB Structures

Chapter 2 - Hardware Installation48Ethernet Single Channel AUI/10BaseT Daughter CardCOMPONENT SIDE Figure 2-6. Ethernet Single Channel AUI/10Ba

Page 83

4221 Condor Hardware Installation Procedures49Dual Channel 10BaseT Ethernet Daughter CardCOMPONENT SIDE Figure 2-7. Dual Channel 10BaseT Ethernet Da

Page 84

Chapter 2 - Hardware Installation50Ethernet Dual Channel AUI Daughter CardCOMPONENT SIDE Figure 2-8. Ethernet Dual Channel AUI Daughter CardNOTE: L

Page 85 - Initialize Controller

4221 Condor Hardware Installation Procedures51Step 5. Power Off SystemOnce the board is configured, ensure that the host system and peripherals are tu

Page 86 - Number of CQE Entries

Chapter 2 - Hardware Installation52RS232 Connectors And CablesThere are two 10 pin connectors (2x5 Headers) which are used as the RS232 port cable con

Page 87 - Special Network Options

53CHAPTER 3MACSI HOST INTERFACEIntroductionThis chapter defines the MACSI host interface for the Interphase V/Ethernet 4221 Condor. The Condor and it

Page 88 - Offboard CRB host address

Chapter 3 - MACSI Host Interface54Field OffsetThe value in the far left column specifies the field offset. This value measures increments of 16 bits

Page 89 - MAC Control/Status

System Interface55System Interface This section defines how the host communicates with the controller. The shared memory interface is defined, and ea

Page 90

Chapter 3 - MACSI Host Interface56The Master Command Entry (MCE) and Command Queue Entries (CQE) are used to queue commands from the hostto the contr

Page 91

Master Control Status Block (MCSB)57Master Control Status Block (MCSB)The MCSB consists of a Master Status Register, which is used to report informati

Page 92 - MAC status/control

viiiMAC status/control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 93

Chapter 3 - MACSI Host Interface58Master Control Register (MCR)The MCR provides the host with infrequently used services. These bits are both set and

Page 94

Onboard Command Queue Entry59Onboard Command Queue Entry The host issues a command to the controller through a Command Queue Entry (CQE). Two types a

Page 95

Chapter 3 - MACSI Host Interface60Fetch offboard (FOB) Setting this bit makes the Command Queue entry an offboard entry. Please see the following sect

Page 96 - MAC returned information

Offboard Command Queue Entry61DMA Transfer Control Word This field specifies how the controller should DMA transfer the data from host memory. This f

Page 97 - Change Default Node Address

Chapter 3 - MACSI Host Interface62Command Response Block (CRB)The CRB is used by the controller to post completed commands back to the host. It consi

Page 98

Command Response Block (CRB)63Error (ER) This bit is set with Command Complete when a returned IOPB completed with an error. Errored commandsare nev

Page 99 - Transmit

Chapter 3 - MACSI Host Interface64Multiple Completed Returned IOPB Structure When multiple commands are returned from the controller to the host with

Page 100 - Transmit -- In-Line Gathers

Configuration Status Block (CSB)65Configuration Status Block (CSB)The controller uses the CSB to report the firmware and hardware configuration upon p

Page 101 - Buffer address

Chapter 3 - MACSI Host Interface66Firmware Revision Level The firmware revision level, represented as a 3-digit ASCII value. Firmware Revision Date Th

Page 102 - Receive

Controller Statistics Block67Controller Statistics Block This space was used to report network statistics in the original Eagle MACSI implementation f

Page 103 - Command Code

ixOperating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 104 - Source Address

Chapter 3 - MACSI Host Interface68Transmit Commands Submitted Total number of attempted frame transmissions (successful and unsuccessful). Transmit DM

Page 105

Controller Statistics Block69Transmit Completions Posted to Host Total number of frame completions posted to the Command Response Block and Returned I

Page 106

Chapter 3 - MACSI Host Interface70IO Parameter Blocks (IOPBs) This section provides a detailed description of each of the commands used by the host to

Page 107 - Report Network Statistics

Common IOPB Structures71Command Code This field specifies the command to be executed. Particular values are noted for each of the individual commands

Page 108 - Timer Interval

Chapter 3 - MACSI Host Interface72Address modifier This field contains the VMEbus address modifier used for the transfer. Refer to your system documen

Page 109 - Network Statistics Block

Initialize Controller73Initialize Controller This command allows the host to specify global configuration parameters, and initializes the controller f

Page 110

Chapter 3 - MACSI Host Interface74Controller Initialization Block (CIB)The CIB contains the actual values to use when initializing the controller. It

Page 111 - SPECIFICATIONS

Controller Initialization Block (CIB)75Special Network Options Originally, this field allowed the host to set several network related options, such as

Page 112 - Reliability

Chapter 3 - MACSI Host Interface76A value between 1 and 0x20 (40 decimal) causes the controller, after being granted the bus, to transfer data until 1

Page 113 - CONNECTOR PINOUTS AND CABLING

MAC Control/Status77MAC Control/Status This command provides a host driver with two distinct levels of service to an Ethernet port located on the 4221

Page 114 - VMEbus Connectors

LIST OF FIGURESxiiFigure 1-1. 4221 Condor Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 115

Chapter 3 - MACSI Host Interface78Table 3-22. MAC Control / StatusCommand Code This field must contain 0x43 to execute the MAC Control IOPB. MAC Contr

Page 116 - 10BaseT Connector Signals

MAC Control/Status79Command Options Table 3-23. Command OptionsInterrupt Enable (IE) Defined in Common IOPB Structures. Set MAC options (SM) When this

Page 117 - AUI Connector Signals

Chapter 3 - MACSI Host Interface80Abort Report (AR)Setting this bit causes commands aborted with either the AA or the AN bit to be reported back to th

Page 118 - RS232 Connector and Cable

MAC Control/Status81Setting this bit resets the port: promiscuous mode is disabled, multicast is disabled, any supplied multipleindividual addresses a

Page 119 - ERROR CODES

Chapter 3 - MACSI Host Interface82Table 3-25. Intel 82596 Transmit Status / ControlBackoff method (BM) (p. 4-131) This parameter determines when to st

Page 120 - Appendix B

MAC Control/Status83Table 3-26. Intel 82596 Receive Status / ControlSave bad frames (SB) (p. 4-129)When set bad frames (CRC error, Alignment error, et

Page 121

Chapter 3 - MACSI Host Interface84Time domain reflectometry test (TDR) (p. 4-150) This operation activates the Time Domain Reflectometry test. The re

Page 122

Change Default Node Address85Change Default Node Address This command is used to change the 48 bit physical address associated with any of the attache

Page 123

Chapter 3 - MACSI Host Interface86Command Options Table 3-28. Command OptionsInterrupt enable (IE)As defined in the Common IOPB Structures. Update use

Page 124

Transmit87Transmit The Transmit command causes the controller to DMA transfer the specified frame from host memory, and thentransmit it (if possible)

Commentaires sur ces manuels

Pas de commentaire